Drug Name
: NA
Drug Role
: It consists of a threaded screw attached to a handle, which is driven into the myoma to provide a firm grip, allowing surgeons to apply traction and facilitate removal of the tumour from the uterine wall.
Please login / register to buy or to get detailed information of the product
SKU:
Stock Available:
Batch / Lot. No:
Shelf life:
Manufacturing Date:
-
Expiry Date:
-
Minimum Pack Size:
Minimum Order Qty:
1
Pharma Categories:
Gynaecological Surgical Instruments.
Product Form:
Reusable stainless steel instrument with screw tip and ergonomic handle.
Category:
Veterinary
Group:
N/A
Type:
• Straight shaft with a sturdy handle for effective traction.
Material:
• Made from surgical-grade stainless steel ensuring durability, corrosion resistance, and ease of sterilization.
HSN Code:
9018
HS Code:
9018.90
Country of Origin:
india
TAX:
5%
Qty per Piece:
Weight Of Each Piece:
Piece Dimensions (L×W×H):
Qty per Buffer Box / Shrink Pack:
Weight of Buffer Box / Shrink Pack:
Buffer Dimensions (L×W×H):
Total Qty per Case:
Total Weight per Case:
Case Dimensions (L×W×H):
Weight / Volume:
Dimensions:
Inhouse product
Doyen's Myoma Screw is a specialized surgical instrument used primarily in gynaecological surgeries to extract myomas (uterine fibroids). It consists of a threaded screw attached to a handle, which is driven into the myoma to provide a firm grip, allowing surgeons to apply traction and facilitate removal of the tumour from the uterine wall.
• Material: High-quality surgical-grade stainless steel
• Length: Typically ranges from 15 cm to 25 cm
• Handle: Ergonomic with knurled grip for secure handling
• Screw Diameter: Usually between 8 mm to 15 mm depending on size
• Available in various sizes to accommodate different myoma sizes and surgical requirements.
• Features a sharp, threaded screw tip for firm anchoring into the myoma tissue.
• Straight shaft with a sturdy handle for effective traction.
• Made from surgical-grade stainless steel ensuring durability, corrosion resistance, and ease of sterilization.
Gynaecological Surgical Instruments.
Reusable stainless steel instrument with screw tip and ergonomic handle.
• Used in gynaecological surgeries to firmly grip and extract uterine fibroids (myomas).
• Provides traction and control during removal procedures.
• Provides strong grip on fibroids ensuring effective traction.
• Durable and reusable after sterilization.
• Ergonomic handle design reduces surgeon fatigue.
• Requires careful handling to avoid tissue damage.
• Limited to use in gynaecological surgeries involving myomas.
• Ensure proper sterilization before and after use.
• Use with care to avoid excessive force which may damage surrounding tissues.
• Inspect instrument regularly for damage or wear.
• HS Code: 9018.90 – Instruments and appliances used in medical, surgical, dental or veterinary sciences
• HSN Code: 9018
• Use surgical gloves when handling during procedures to maintain sterility.
• Apply controlled traction using the handle to avoid tissue injury.
• Suitable for autoclaving and standard sterilization methods for surgical instruments.
• Primarily used in human gynaecological surgeries for myoma removal.
• Rarely used in veterinary medicine; mainly a human surgical instrument.
Q1: What is Doyen's Myoma Screw used for? A1: It is used to grip and extract uterine fibroids (myomas) during gynaecological surgery.
Q2: Is it reusable? A2: Yes, made of surgical-grade stainless steel, it can be sterilized and reused.
Q3: Can it be used in veterinary surgeries? A3: It is primarily designed for human gynaecological procedures.
Q4: How is the screw tip designed? A4: It features a sharp, threaded tip for secure anchoring into the myoma tissue.
Q5: What sterilization methods are recommended? A5: Autoclaving and standard surgical instrument sterilization methods are recommended.
Secure Transaction
100% secure payment
Top Brand
Trusted quality
Non Return
Due to hygiene
Doyen's Myoma Screw is a specialized surgical instrument used primarily in gynaecological surgeries to extract myomas (uterine fibroids). It consists of a threaded screw attached to a handle, which is driven into the myoma to provide a firm grip, allowing surgeons to apply traction and facilitate removal of the tumour from the uterine wall.
• Material: High-quality surgical-grade stainless steel
• Length: Typically ranges from 15 cm to 25 cm
• Handle: Ergonomic with knurled grip for secure handling
• Screw Diameter: Usually between 8 mm to 15 mm depending on size
• Available in various sizes to accommodate different myoma sizes and surgical requirements.
• Features a sharp, threaded screw tip for firm anchoring into the myoma tissue.
• Straight shaft with a sturdy handle for effective traction.
• Made from surgical-grade stainless steel ensuring durability, corrosion resistance, and ease of sterilization.
Gynaecological Surgical Instruments.
Reusable stainless steel instrument with screw tip and ergonomic handle.
• Used in gynaecological surgeries to firmly grip and extract uterine fibroids (myomas).
• Provides traction and control during removal procedures.
• Provides strong grip on fibroids ensuring effective traction.
• Durable and reusable after sterilization.
• Ergonomic handle design reduces surgeon fatigue.
• Requires careful handling to avoid tissue damage.
• Limited to use in gynaecological surgeries involving myomas.
• Ensure proper sterilization before and after use.
• Use with care to avoid excessive force which may damage surrounding tissues.
• Inspect instrument regularly for damage or wear.
• HS Code: 9018.90 – Instruments and appliances used in medical, surgical, dental or veterinary sciences
• HSN Code: 9018
• Use surgical gloves when handling during procedures to maintain sterility.
• Apply controlled traction using the handle to avoid tissue injury.
• Suitable for autoclaving and standard sterilization methods for surgical instruments.
• Primarily used in human gynaecological surgeries for myoma removal.
• Rarely used in veterinary medicine; mainly a human surgical instrument.
Q1: What is Doyen's Myoma Screw used for? A1: It is used to grip and extract uterine fibroids (myomas) during gynaecological surgery.
Q2: Is it reusable? A2: Yes, made of surgical-grade stainless steel, it can be sterilized and reused.
Q3: Can it be used in veterinary surgeries? A3: It is primarily designed for human gynaecological procedures.
Q4: How is the screw tip designed? A4: It features a sharp, threaded tip for secure anchoring into the myoma tissue.
Q5: What sterilization methods are recommended? A5: Autoclaving and standard surgical instrument sterilization methods are recommended.